A New Method Of Establishing The State Of Charge Of Lead-Acid Batteries With Electrolyte Circulation

Abstract

The proposed method of monitoring battery state-of-charge is based on electrolyte density measurements. It is reliable, applicable in all cases to batteries with a circulating electrolyte, and is very useful for high discharge rates.
An empirical law, based on results obtained from different experiments has been developed. This law allows isolation of the accumulator state-ofcharge as a function of the maximum state-of-charge density at the test point and a proportionality constant, n.